aboutsummaryrefslogtreecommitdiff
path: root/thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts
diff options
context:
space:
mode:
Diffstat (limited to 'thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts')
-rw-r--r--thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts/ble_hts.c462
-rw-r--r--thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts/ble_hts.h219
2 files changed, 681 insertions, 0 deletions
diff --git a/thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts/ble_hts.c b/thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts/ble_hts.c
new file mode 100644
index 0000000..25afa01
--- /dev/null
+++ b/thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts/ble_hts.c
@@ -0,0 +1,462 @@
+/**
+ * Copyright (c) 2012 - 2018, Nordic Semiconductor ASA
+ *
+ * All rights reserved.
+ *
+ * Redistribution and use in source and binary forms, with or without modification,
+ * are permitted provided that the following conditions are met:
+ *
+ * 1. Redistributions of source code must retain the above copyright notice, this
+ * list of conditions and the following disclaimer.
+ *
+ * 2. Redistributions in binary form, except as embedded into a Nordic
+ * Semiconductor ASA integrated circuit in a product or a software update for
+ * such product, must reproduce the above copyright notice, this list of
+ * conditions and the following disclaimer in the documentation and/or other
+ * materials provided with the distribution.
+ *
+ * 3. Neither the name of Nordic Semiconductor ASA nor the names of its
+ * contributors may be used to endorse or promote products derived from this
+ * software without specific prior written permission.
+ *
+ * 4. This software, with or without modification, must only be used with a
+ * Nordic Semiconductor ASA integrated circuit.
+ *
+ * 5. Any software provided in binary form under this license must not be reverse
+ * engineered, decompiled, modified and/or disassembled.
+ *
+ * THIS SOFTWARE IS PROVIDED BY NORDIC SEMICONDUCTOR ASA "AS IS" AND ANY EXPRESS
+ * OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
+ * OF MERCHANTABILITY, NONINFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE ARE
+ * DISCLAIMED. IN NO EVENT SHALL NORDIC SEMICONDUCTOR ASA OR CONTRIBUTORS BE
+ * LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
+ * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE
+ * GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
+ * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
+ * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT
+ * OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+ *
+ */
+/* Attention!
+ * To maintain compliance with Nordic Semiconductor ASA's Bluetooth profile
+ * qualification listings, this section of source code must not be modified.
+ */
+#include "sdk_common.h"
+#if NRF_MODULE_ENABLED(BLE_HTS)
+#include "ble_err.h"
+#include "ble_hts.h"
+#include <string.h>
+#include "ble_srv_common.h"
+
+
+#define OPCODE_LENGTH 1 /**< Length of opcode inside Health Thermometer Measurement packet. */
+#define HANDLE_LENGTH 2 /**< Length of handle inside Health Thermometer Measurement packet. */
+#define MAX_HTM_LEN (BLE_GATT_ATT_MTU_DEFAULT - OPCODE_LENGTH - HANDLE_LENGTH) /**< Maximum size of a transmitted Health Thermometer Measurement. */
+
+// Health Thermometer Measurement flag bits
+#define HTS_MEAS_FLAG_TEMP_UNITS_BIT (0x01 << 0) /**< Temperature Units flag. */
+#define HTS_MEAS_FLAG_TIME_STAMP_BIT (0x01 << 1) /**< Time Stamp flag. */
+#define HTS_MEAS_FLAG_TEMP_TYPE_BIT (0x01 << 2) /**< Temperature Type flag. */
+
+
+/**@brief Function for handling the Connect event.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_ble_evt Event received from the BLE stack.
+ */
+static void on_connect(ble_hts_t * p_hts, ble_evt_t const * p_ble_evt)
+{
+ p_hts->conn_handle = p_ble_evt->evt.gatts_evt.conn_handle;
+}
+
+
+/**@brief Function for handling the Disconnect event.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_ble_evt Event received from the BLE stack.
+ */
+static void on_disconnect(ble_hts_t * p_hts, ble_evt_t const * p_ble_evt)
+{
+ UNUSED_PARAMETER(p_ble_evt);
+ p_hts->conn_handle = BLE_CONN_HANDLE_INVALID;
+}
+
+
+/**@brief Function for handling write events to the Blood Pressure Measurement characteristic.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_evt_write Write event received from the BLE stack.
+ */
+static void on_cccd_write(ble_hts_t * p_hts, ble_gatts_evt_write_t const * p_evt_write)
+{
+ if (p_evt_write->len == 2)
+ {
+ // CCCD written, update indication state
+ if (p_hts->evt_handler != NULL)
+ {
+ ble_hts_evt_t evt;
+
+ if (ble_srv_is_indication_enabled(p_evt_write->data))
+ {
+ evt.evt_type = BLE_HTS_EVT_INDICATION_ENABLED;
+ }
+ else
+ {
+ evt.evt_type = BLE_HTS_EVT_INDICATION_DISABLED;
+ }
+
+ p_hts->evt_handler(p_hts, &evt);
+ }
+ }
+}
+
+
+/**@brief Function for handling the Write event.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_ble_evt Event received from the BLE stack.
+ */
+static void on_write(ble_hts_t * p_hts, ble_evt_t const * p_ble_evt)
+{
+ ble_gatts_evt_write_t const * p_evt_write = &p_ble_evt->evt.gatts_evt.params.write;
+
+ if (p_evt_write->handle == p_hts->meas_handles.cccd_handle)
+ {
+ on_cccd_write(p_hts, p_evt_write);
+ }
+}
+
+
+/**@brief Function for handling the HVC event.
+ *
+ * @details Handles HVC events from the BLE stack.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_ble_evt Event received from the BLE stack.
+ */
+static void on_hvc(ble_hts_t * p_hts, ble_evt_t const * p_ble_evt)
+{
+ ble_gatts_evt_hvc_t const * p_hvc = &p_ble_evt->evt.gatts_evt.params.hvc;
+
+ if (p_hvc->handle == p_hts->meas_handles.value_handle)
+ {
+ ble_hts_evt_t evt;
+
+ evt.evt_type = BLE_HTS_EVT_INDICATION_CONFIRMED;
+ p_hts->evt_handler(p_hts, &evt);
+ }
+}
+
+
+void ble_hts_on_ble_evt(ble_evt_t const * p_ble_evt, void * p_context)
+{
+ ble_hts_t * p_hts = (ble_hts_t *)p_context;
+
+ switch (p_ble_evt->header.evt_id)
+ {
+ case BLE_GAP_EVT_CONNECTED:
+ on_connect(p_hts, p_ble_evt);
+ break;
+
+ case BLE_GAP_EVT_DISCONNECTED:
+ on_disconnect(p_hts, p_ble_evt);
+ break;
+
+ case BLE_GATTS_EVT_WRITE:
+ on_write(p_hts, p_ble_evt);
+ break;
+
+ case BLE_GATTS_EVT_HVC:
+ on_hvc(p_hts, p_ble_evt);
+ break;
+
+ default:
+ // No implementation needed.
+ break;
+ }
+}
+
+
+/**@brief Function for encoding a Health Thermometer Measurement.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_hts_meas Measurement to be encoded.
+ * @param[out] p_encoded_buffer Buffer where the encoded data will be written.
+ *
+ * @return Size of encoded data.
+ */
+static uint8_t hts_measurement_encode(ble_hts_t * p_hts,
+ ble_hts_meas_t * p_hts_meas,
+ uint8_t * p_encoded_buffer)
+{
+ uint8_t flags = 0;
+ uint8_t len = 1;
+ uint32_t encoded_temp;
+
+ // Flags field
+ if (p_hts_meas->temp_in_fahr_units)
+ {
+ flags |= HTS_MEAS_FLAG_TEMP_UNITS_BIT;
+ }
+ if (p_hts_meas->time_stamp_present)
+ {
+ flags |= HTS_MEAS_FLAG_TIME_STAMP_BIT;
+ }
+
+ // Temperature Measurement Value field
+ if (p_hts_meas->temp_in_fahr_units)
+ {
+ flags |= HTS_MEAS_FLAG_TEMP_UNITS_BIT;
+
+ encoded_temp = ((p_hts_meas->temp_in_fahr.exponent << 24) & 0xFF000000) |
+ ((p_hts_meas->temp_in_fahr.mantissa << 0) & 0x00FFFFFF);
+ }
+ else
+ {
+ encoded_temp = ((p_hts_meas->temp_in_celcius.exponent << 24) & 0xFF000000) |
+ ((p_hts_meas->temp_in_celcius.mantissa << 0) & 0x00FFFFFF);
+ }
+ len += uint32_encode(encoded_temp, &p_encoded_buffer[len]);
+
+ // Time Stamp field
+ if (p_hts_meas->time_stamp_present)
+ {
+ flags |= HTS_MEAS_FLAG_TIME_STAMP_BIT;
+ len += ble_date_time_encode(&p_hts_meas->time_stamp, &p_encoded_buffer[len]);
+ }
+
+ // Temperature Type field
+ if (p_hts_meas->temp_type_present)
+ {
+ flags |= HTS_MEAS_FLAG_TEMP_TYPE_BIT;
+ p_encoded_buffer[len++] = p_hts_meas->temp_type;
+ }
+
+ // Flags field
+ p_encoded_buffer[0] = flags;
+
+ return len;
+}
+
+
+/**@brief Function for adding Health Thermometer Measurement characteristics.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_hts_init Information needed to initialize the service.
+ *
+ * @return NRF_SUCCESS on success, otherwise an error code.
+ */
+static uint32_t hts_measurement_char_add(ble_hts_t * p_hts, ble_hts_init_t const * p_hts_init)
+{
+ ble_gatts_char_md_t char_md;
+ ble_gatts_attr_md_t cccd_md;
+ ble_gatts_attr_t attr_char_value;
+ ble_uuid_t ble_uuid;
+ ble_gatts_attr_md_t attr_md;
+ ble_hts_meas_t initial_htm;
+ uint8_t encoded_htm[MAX_HTM_LEN];
+
+ memset(&cccd_md, 0, sizeof(cccd_md));
+
+ BLE_GAP_CONN_SEC_MODE_SET_OPEN(&cccd_md.read_perm);
+ cccd_md.vloc = BLE_GATTS_VLOC_STACK;
+ cccd_md.write_perm = p_hts_init->hts_meas_attr_md.cccd_write_perm;
+
+ memset(&char_md, 0, sizeof(char_md));
+
+ char_md.char_props.indicate = 1;
+ char_md.p_char_user_desc = NULL;
+ char_md.p_char_pf = NULL;
+ char_md.p_user_desc_md = NULL;
+ char_md.p_cccd_md = &cccd_md;
+ char_md.p_sccd_md = NULL;
+
+ BLE_UUID_BLE_ASSIGN(ble_uuid, BLE_UUID_TEMPERATURE_MEASUREMENT_CHAR);
+
+ memset(&attr_md, 0, sizeof(attr_md));
+
+ attr_md.vloc = BLE_GATTS_VLOC_STACK;
+ attr_md.read_perm = p_hts_init->hts_meas_attr_md.read_perm;
+ attr_md.write_perm = p_hts_init->hts_meas_attr_md.write_perm;
+ attr_md.rd_auth = 0;
+ attr_md.wr_auth = 0;
+ attr_md.vlen = 1;
+
+ memset(&attr_char_value, 0, sizeof(attr_char_value));
+ memset(&initial_htm, 0, sizeof(initial_htm));
+
+ attr_char_value.p_uuid = &ble_uuid;
+ attr_char_value.p_attr_md = &attr_md;
+ attr_char_value.init_len = hts_measurement_encode(p_hts, &initial_htm, encoded_htm);
+ attr_char_value.init_offs = 0;
+ attr_char_value.max_len = MAX_HTM_LEN;
+ attr_char_value.p_value = encoded_htm;
+
+ return sd_ble_gatts_characteristic_add(p_hts->service_handle,
+ &char_md,
+ &attr_char_value,
+ &p_hts->meas_handles);
+}
+
+
+/**@brief Function for adding Temperature Type characteristics.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_hts_init Information needed to initialize the service.
+ *
+ * @return NRF_SUCCESS on success, otherwise an error code.
+ */
+static uint32_t hts_temp_type_char_add(ble_hts_t * p_hts, ble_hts_init_t const * p_hts_init)
+{
+ ble_gatts_char_md_t char_md;
+ ble_gatts_attr_t attr_char_value;
+ ble_uuid_t ble_uuid;
+ ble_gatts_attr_md_t attr_md;
+ uint8_t init_value_temp_type;
+ uint8_t init_value_encoded[1];
+
+ memset(&char_md, 0, sizeof(char_md));
+
+ char_md.char_props.read = 1;
+ char_md.p_char_user_desc = NULL;
+ char_md.p_char_pf = NULL;
+ char_md.p_user_desc_md = NULL;
+ char_md.p_cccd_md = NULL;
+ char_md.p_sccd_md = NULL;
+
+ BLE_UUID_BLE_ASSIGN(ble_uuid, BLE_UUID_TEMPERATURE_TYPE_CHAR);
+
+ memset(&attr_md, 0, sizeof(attr_md));
+
+ attr_md.vloc = BLE_GATTS_VLOC_STACK;
+ attr_md.read_perm = p_hts_init->hts_temp_type_attr_md.read_perm;
+ attr_md.write_perm = p_hts_init->hts_temp_type_attr_md.write_perm;
+ attr_md.rd_auth = 0;
+ attr_md.wr_auth = 0;
+ attr_md.vlen = 0;
+
+ memset(&attr_char_value, 0, sizeof(attr_char_value));
+
+ init_value_temp_type = p_hts_init->temp_type;
+ init_value_encoded[0] = init_value_temp_type;
+
+ attr_char_value.p_uuid = &ble_uuid;
+ attr_char_value.p_attr_md = &attr_md;
+ attr_char_value.init_len = sizeof (uint8_t);
+ attr_char_value.init_offs = 0;
+ attr_char_value.max_len = sizeof (uint8_t);
+ attr_char_value.p_value = init_value_encoded;
+
+ return sd_ble_gatts_characteristic_add(p_hts->service_handle,
+ &char_md,
+ &attr_char_value,
+ &p_hts->temp_type_handles);
+}
+
+
+uint32_t ble_hts_init(ble_hts_t * p_hts, ble_hts_init_t const * p_hts_init)
+{
+ uint32_t err_code;
+ ble_uuid_t ble_uuid;
+
+ // Initialize service structure
+ p_hts->evt_handler = p_hts_init->evt_handler;
+ p_hts->conn_handle = BLE_CONN_HANDLE_INVALID;
+ p_hts->temp_type = p_hts_init->temp_type;
+
+ // Add service
+ BLE_UUID_BLE_ASSIGN(ble_uuid, BLE_UUID_HEALTH_THERMOMETER_SERVICE);
+
+ err_code = sd_ble_gatts_service_add(BLE_GATTS_SRVC_TYPE_PRIMARY, &ble_uuid, &p_hts->service_handle);
+ if (err_code != NRF_SUCCESS)
+ {
+ return err_code;
+ }
+
+ // Add measurement characteristic
+ err_code = hts_measurement_char_add(p_hts, p_hts_init);
+ if (err_code != NRF_SUCCESS)
+ {
+ return err_code;
+ }
+
+ // Add temperature type characteristic
+ if (p_hts_init->temp_type_as_characteristic)
+ {
+ err_code = hts_temp_type_char_add(p_hts, p_hts_init);
+ if (err_code != NRF_SUCCESS)
+ {
+ return err_code;
+ }
+ }
+
+ return NRF_SUCCESS;
+}
+
+
+uint32_t ble_hts_measurement_send(ble_hts_t * p_hts, ble_hts_meas_t * p_hts_meas)
+{
+ uint32_t err_code;
+
+ // Send value if connected
+ if (p_hts->conn_handle != BLE_CONN_HANDLE_INVALID)
+ {
+ uint8_t encoded_hts_meas[MAX_HTM_LEN];
+ uint16_t len;
+ uint16_t hvx_len;
+ ble_gatts_hvx_params_t hvx_params;
+
+ len = hts_measurement_encode(p_hts, p_hts_meas, encoded_hts_meas);
+ hvx_len = len;
+
+ memset(&hvx_params, 0, sizeof(hvx_params));
+
+ hvx_params.handle = p_hts->meas_handles.value_handle;
+ hvx_params.type = BLE_GATT_HVX_INDICATION;
+ hvx_params.offset = 0;
+ hvx_params.p_len = &hvx_len;
+ hvx_params.p_data = encoded_hts_meas;
+
+ err_code = sd_ble_gatts_hvx(p_hts->conn_handle, &hvx_params);
+ if ((err_code == NRF_SUCCESS) && (hvx_len != len))
+ {
+ err_code = NRF_ERROR_DATA_SIZE;
+ }
+ }
+ else
+ {
+ err_code = NRF_ERROR_INVALID_STATE;
+ }
+
+ return err_code;
+}
+
+
+uint32_t ble_hts_is_indication_enabled(ble_hts_t * p_hts, bool * p_indication_enabled)
+{
+ uint32_t err_code;
+ uint8_t cccd_value_buf[BLE_CCCD_VALUE_LEN];
+ ble_gatts_value_t gatts_value;
+
+ // Initialize value struct.
+ memset(&gatts_value, 0, sizeof(gatts_value));
+
+ gatts_value.len = BLE_CCCD_VALUE_LEN;
+ gatts_value.offset = 0;
+ gatts_value.p_value = cccd_value_buf;
+
+ err_code = sd_ble_gatts_value_get(p_hts->conn_handle,
+ p_hts->meas_handles.cccd_handle,
+ &gatts_value);
+ if (err_code == NRF_SUCCESS)
+ {
+ *p_indication_enabled = ble_srv_is_indication_enabled(cccd_value_buf);
+ }
+ if (err_code == BLE_ERROR_GATTS_SYS_ATTR_MISSING)
+ {
+ *p_indication_enabled = false;
+ return NRF_SUCCESS;
+ }
+ return err_code;
+}
+#endif // NRF_MODULE_ENABLED(BLE_HTS)
diff --git a/thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts/ble_hts.h b/thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts/ble_hts.h
new file mode 100644
index 0000000..a9f76cd
--- /dev/null
+++ b/thirdparty/nRF5_SDK_15.0.0_a53641a/components/ble/ble_services/ble_hts/ble_hts.h
@@ -0,0 +1,219 @@
+/**
+ * Copyright (c) 2012 - 2018, Nordic Semiconductor ASA
+ *
+ * All rights reserved.
+ *
+ * Redistribution and use in source and binary forms, with or without modification,
+ * are permitted provided that the following conditions are met:
+ *
+ * 1. Redistributions of source code must retain the above copyright notice, this
+ * list of conditions and the following disclaimer.
+ *
+ * 2. Redistributions in binary form, except as embedded into a Nordic
+ * Semiconductor ASA integrated circuit in a product or a software update for
+ * such product, must reproduce the above copyright notice, this list of
+ * conditions and the following disclaimer in the documentation and/or other
+ * materials provided with the distribution.
+ *
+ * 3. Neither the name of Nordic Semiconductor ASA nor the names of its
+ * contributors may be used to endorse or promote products derived from this
+ * software without specific prior written permission.
+ *
+ * 4. This software, with or without modification, must only be used with a
+ * Nordic Semiconductor ASA integrated circuit.
+ *
+ * 5. Any software provided in binary form under this license must not be reverse
+ * engineered, decompiled, modified and/or disassembled.
+ *
+ * THIS SOFTWARE IS PROVIDED BY NORDIC SEMICONDUCTOR ASA "AS IS" AND ANY EXPRESS
+ * OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
+ * OF MERCHANTABILITY, NONINFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE ARE
+ * DISCLAIMED. IN NO EVENT SHALL NORDIC SEMICONDUCTOR ASA OR CONTRIBUTORS BE
+ * LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
+ * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE
+ * GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
+ * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
+ * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT
+ * OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+ *
+ */
+/** @file
+ *
+ * @defgroup ble_hts Health Thermometer Service
+ * @{
+ * @ingroup ble_sdk_srv
+ * @brief Health Thermometer Service module.
+ *
+ * @details This module implements the Health Thermometer Service.
+ *
+ * If an event handler is supplied by the application, the Health Thermometer
+ * Service will generate Health Thermometer Service events to the application.
+ *
+ * @note The application must register this module as BLE event observer using the
+ * NRF_SDH_BLE_OBSERVER macro. Example:
+ * @code
+ * ble_hts_t instance;
+ * NRF_SDH_BLE_OBSERVER(anything, BLE_HTS_BLE_OBSERVER_PRIO,
+ * ble_hts_on_ble_evt, &instance);
+ * @endcode
+ *
+ * @note Attention!
+ * To maintain compliance with Nordic Semiconductor ASA Bluetooth profile
+ * qualification listings, this section of source code must not be modified.
+ */
+
+#ifndef BLE_HTS_H__
+#define BLE_HTS_H__
+
+#include <stdint.h>
+#include <stdbool.h>
+#include "ble.h"
+#include "ble_srv_common.h"
+#include "ble_date_time.h"
+#include "nrf_sdh_ble.h"
+
+#ifdef __cplusplus
+extern "C" {
+#endif
+
+/**@brief Macro for defining a ble_hts instance.
+ *
+ * @param _name Name of the instance.
+ * @hideinitializer
+ */
+#define BLE_HTS_DEF(_name) \
+static ble_hts_t _name; \
+NRF_SDH_BLE_OBSERVER(_name ## _obs, \
+ BLE_HTS_BLE_OBSERVER_PRIO, \
+ ble_hts_on_ble_evt, &_name)
+
+// Temperature Type measurement locations
+#define BLE_HTS_TEMP_TYPE_ARMPIT 1
+#define BLE_HTS_TEMP_TYPE_BODY 2
+#define BLE_HTS_TEMP_TYPE_EAR 3
+#define BLE_HTS_TEMP_TYPE_FINGER 4
+#define BLE_HTS_TEMP_TYPE_GI_TRACT 5
+#define BLE_HTS_TEMP_TYPE_MOUTH 6
+#define BLE_HTS_TEMP_TYPE_RECTUM 7
+#define BLE_HTS_TEMP_TYPE_TOE 8
+#define BLE_HTS_TEMP_TYPE_EAR_DRUM 9
+
+
+/**@brief Health Thermometer Service event type. */
+typedef enum
+{
+ BLE_HTS_EVT_INDICATION_ENABLED, /**< Health Thermometer value indication enabled event. */
+ BLE_HTS_EVT_INDICATION_DISABLED, /**< Health Thermometer value indication disabled event. */
+ BLE_HTS_EVT_INDICATION_CONFIRMED /**< Confirmation of a temperature measurement indication has been received. */
+} ble_hts_evt_type_t;
+
+/**@brief Health Thermometer Service event. */
+typedef struct
+{
+ ble_hts_evt_type_t evt_type; /**< Type of event. */
+} ble_hts_evt_t;
+
+// Forward declaration of the ble_hts_t type.
+typedef struct ble_hts_s ble_hts_t;
+
+/**@brief Health Thermometer Service event handler type. */
+typedef void (*ble_hts_evt_handler_t) (ble_hts_t * p_hts, ble_hts_evt_t * p_evt);
+
+/**@brief FLOAT format (IEEE-11073 32-bit FLOAT, defined as a 32-bit value with a 24-bit mantissa
+ * and an 8-bit exponent. */
+typedef struct
+{
+ int8_t exponent; /**< Base 10 exponent */
+ int32_t mantissa; /**< Mantissa, should be using only 24 bits */
+} ieee_float32_t;
+
+/**@brief Health Thermometer Service init structure. This contains all options and data
+ * needed for initialization of the service. */
+typedef struct
+{
+ ble_hts_evt_handler_t evt_handler; /**< Event handler to be called for handling events in the Health Thermometer Service. */
+ ble_srv_cccd_security_mode_t hts_meas_attr_md; /**< Initial security level for health thermometer measurement attribute */
+ ble_srv_security_mode_t hts_temp_type_attr_md; /**< Initial security level for health thermometer tempearture type attribute */
+ uint8_t temp_type_as_characteristic; /**< Set non-zero if temp type given as characteristic */
+ uint8_t temp_type; /**< Temperature type if temperature characteristic is used */
+} ble_hts_init_t;
+
+/**@brief Health Thermometer Service structure. This contains various status information for
+ * the service. */
+struct ble_hts_s
+{
+ ble_hts_evt_handler_t evt_handler; /**< Event handler to be called for handling events in the Health Thermometer Service. */
+ uint16_t service_handle; /**< Handle of Health Thermometer Service (as provided by the BLE stack). */
+ ble_gatts_char_handles_t meas_handles; /**< Handles related to the Health Thermometer Measurement characteristic. */
+ ble_gatts_char_handles_t temp_type_handles; /**< Handles related to the Health Thermometer Temperature Type characteristic. */
+ uint16_t conn_handle; /**< Handle of the current connection (as provided by the BLE stack, is BLE_CONN_HANDLE_INVALID if not in a connection). */
+ uint8_t temp_type; /**< Temperature type indicates where the measurement was taken. */
+};
+
+/**@brief Health Thermometer Service measurement structure. This contains a Health Thermometer
+ * measurement. */
+typedef struct ble_hts_meas_s
+{
+ bool temp_in_fahr_units; /**< True if Temperature is in Fahrenheit units, Celcius otherwise. */
+ bool time_stamp_present; /**< True if Time Stamp is present. */
+ bool temp_type_present; /**< True if Temperature Type is present. */
+ ieee_float32_t temp_in_celcius; /**< Temperature Measurement Value (Celcius). */
+ ieee_float32_t temp_in_fahr; /**< Temperature Measurement Value (Fahrenheit). */
+ ble_date_time_t time_stamp; /**< Time Stamp. */
+ uint8_t temp_type; /**< Temperature Type. */
+} ble_hts_meas_t;
+
+
+/**@brief Function for initializing the Health Thermometer Service.
+ *
+ * @param[out] p_hts Health Thermometer Service structure. This structure will have to
+ * be supplied by the application. It will be initialized by this function,
+ * and will later be used to identify this particular service instance.
+ * @param[in] p_hts_init Information needed to initialize the service.
+ *
+ * @return NRF_SUCCESS on successful initialization of service, otherwise an error code.
+ */
+uint32_t ble_hts_init(ble_hts_t * p_hts, const ble_hts_init_t * p_hts_init);
+
+
+/**@brief Function for handling the Application's BLE Stack events.
+ *
+ * @details Handles all events from the BLE stack of interest to the Health Thermometer Service.
+ *
+ * @param[in] p_ble_evt Event received from the BLE stack.
+ * @param[in] p_context Health Thermometer Service structure.
+ */
+void ble_hts_on_ble_evt(ble_evt_t const * p_ble_evt, void * p_context);
+
+
+/**@brief Function for sending health thermometer measurement if indication has been enabled.
+ *
+ * @details The application calls this function after having performed a Health Thermometer
+ * measurement. If indication has been enabled, the measurement data is encoded and
+ * sent to the client.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[in] p_hts_meas Pointer to new health thermometer measurement.
+ *
+ * @return NRF_SUCCESS on success, otherwise an error code.
+ */
+uint32_t ble_hts_measurement_send(ble_hts_t * p_hts, ble_hts_meas_t * p_hts_meas);
+
+
+/**@brief Function for checking if indication of Temperature Measurement is currently enabled.
+ *
+ * @param[in] p_hts Health Thermometer Service structure.
+ * @param[out] p_indication_enabled TRUE if indication is enabled, FALSE otherwise.
+ *
+ * @return NRF_SUCCESS on success, otherwise an error code.
+ */
+uint32_t ble_hts_is_indication_enabled(ble_hts_t * p_hts, bool * p_indication_enabled);
+
+
+#ifdef __cplusplus
+}
+#endif
+
+#endif // BLE_HTS_H__
+
+/** @} */